Two installers blowing insulation across a dark cold attic
Home › Roof and Cathedral Ceiling Insulation

Roof and Cathedral Ceiling Insulation in Toledo

Yes, we can spray foam the underside of your roof. We put foam or rigid foam board against the roof deck, or fill a cathedral ceiling from inside, and we never work on top of the roof. Book a free inspection and we'll tell you which fits your house.

  • Licensed & insured
  • Free estimates
  • Financing available
  • Workmanship warranty
Free insulation estimateTell us about the house. We will call to set a time.

No spam, ever. By submitting, you agree to our Privacy Policy.

Insulating under the roof deck

We spray foam or fit rigid foam board against the underside of the roof deck, between the rafters. The roof deck becomes the top of your insulated house, which suits an attic you store things in or plan to finish.

Closed-cell foam is denser and goes on thin, so it fits where the rafters are shallow. Open-cell foam is softer and fills a deeper cavity for less money per board foot. Open cell vs closed cell lays out the difference. Rigid board is cut to fit between rafters and sealed at the edges; see foam board insulation.

For a typical roofline job, 1,400 to 2,200 sq ft of roof deck and gable walls inside a 1,000 to 1,800 sq ft attic, our installed price for closed-cell foam 3 inches thick runs $4,200 to $9,900. An ignition barrier coating, where it's required, is a separate line. The free inspection gives the exact price for your roof, and our spray foam cost page shows how we price it.

Toledo averages about 37 inches of snow a year (1991-2020). When house heat warms the roof deck, that snow melts and refreezes at the eaves as ice dams. Insulating at the deck, along with air sealing, cuts the heat that reaches it.

Closed-cell foam under roof deck beside sealed box

Cathedral ceilings

How we insulate a cathedral ceiling depends on what's behind the drywall. If the rafters are open, we spray foam between them. If the ceiling is already closed in, we can blow dense-pack cellulose into the rafter bays through small holes and patch them. Cellulose insulation explains how dense-pack works.

Depth is the limit. A rafter is only so deep, and that caps how much insulation fits. Foam gives more R-value per inch than batts, so it often fits where batts can't. For a 400 to 600 sq ft vaulted ceiling, our installed price runs $2,200 to $4,950 for 5.5 inches of closed-cell foam in open rafters, $700 to $3,150 for 7 inches of open-cell, and $700 to $2,100 to dense-pack closed rafter bays. We check how your roof is built and tell you what will work before we quote.

In a living space, foam gets covered by drywall or another approved barrier. We plan that into the job from the start.

What Ohio's code asks for on an unvented roof in zone 5

If the underside of your roof is insulated and the attic is unvented, Ohio's code asks for R-20 against the deck for condensation control (Table 806.5). Toledo is in climate zone 5.

The reason is simple. Warm, damp air from the house reaches the cold roof deck and condenses on it, and wet decking rots. Insulation pressed against the deck keeps that air away. So we put the R-20 on the deck itself, not in batts hung below it. More on the foam itself is on our spray foam page.

That R-20 is about keeping the deck dry. It isn't the full amount of insulation for the house. The R-value guide has the numbers.

What we don't do: spray foam roofing

We don't do spray foam roofing. That's the exterior foam-and-coating roof put on from above, and it's roofing work. We insulate from inside, under the deck.

If your roof is already leaking, get the leak repaired first. Insulation under the deck won't fix it, and we'll look at the underside of the deck at the inspection.

Attic floor or a metal barn roof?

If your attic is open and you only want more insulation on the floor, that's a different job, covered on our attic insulation page. Insulating the underside of a metal barn roof is covered on our pole barn page.

Common questions

Does foam under the roof have to be covered?

Yes. Ohio's code requires spray foam and foam board inside the home to be covered by an approved thermal barrier, such as 1/2-inch drywall. In an attic, an ignition barrier can be used instead: such as 1-1/2-inch mineral fiber, 1/4-inch wood structural panel or 3/8-inch gypsum board, if the section's other conditions are also met.

Book your free roof insulation inspection in Toledo

We'll look at the underside of your roof, tell you which option fits, and give you a written scope. Call us or request your free estimate.

Licensed & insured · Free estimates

More from our insulation team

Sources for the local facts on this page
Call (419) 574-6781 Free Estimate